__DEV – dropControllerV4 Manual Drain

 
dropControllerV4 has a very handy manual drain function that is operated from the device and does not require the app.

These is also a drain function within the app if you prefer using the app.

dropControllerV4 manual drain function
The Manual drain function is controlled using the SEL and SET buttons.

 
To enter the Manual Drain function, at the main screen, click the SEL button

The screen changes to show the Manual Drain menu.
When first entering Manual Drain the valve is set at valve 1. This corresponds to the valve port on the back of the dropController.

Clicking the SEL button again increments the valve number and will cycle through all 8 valve ports. The sequence is:
1=>2=>3=>4=>5=>6=>7=>8=>EXIT

When EXIT is displayed, click the SET button to exit and return to the main screen.

 

Open and Close a valve

To open a valve, enter the Manual Drain function, use the SEL button to select the valve you want to open and click the SET button. To close the valve click the SET button again.

Valve 1 i selected. Press the SET button to open the valve. Press the SET button again to close the valve.

While the valve is open the time out counter will count down to zero. When the counter reaches zero the valve will automatically close.

Pressing the SEL button while a valve is open will close the current valve and move to the next valve (or EXIT if the current valve is number 8).

 

Setting the time out time

Some solenoid valves can be become hot when left open for long periods of time. To help prevent this, the dropControllerV4 drain function has an automatic time out. When a valve is opened the count down timer will start, when the counter reaches zero the valve will automatically close.

By default the valve open time out is set to 10 seconds. This can be changed in the time out information screen.
From the main screen, clicking the SET button will enter sho various information screens. There are 3 screens and clicking the SET button moves through them: Netork Credentials => Valve Drain Timeout => Version.

To change the valve drain time out value, go to the valve drain page and click the SET button. Clicking SET will increase the time out by 10 seconds: 10 => 20 => 30 => 40 => 50 => 60 => 10…

The minimum is 10 seconds. The maximum is 60 seconds.

The new time is automatically saved.